0
RESEARCH PAPERS

Fundamental Study on the Super-Long-Period Active Isolation System

[+] Author and Article Information
Keisuke Minagawa

Graduate School of Engineering, Tokyo Denki University, 2-2 Kanda-Nishiki-cho, Chiyoda-ku, Tokyo 101-8457, Japan04gdm01@ed.cck.dendai.ac.jp

Satoshi Fujita

Department of Mechanical Engineering, Tokyo Denki University, 2-2 Kanda-Nishiki-cho, Chiyoda-ku, Tokyo 101-8457, Japansfujita@cck.dendai.ac.jp

J. Pressure Vessel Technol 128(4), 502-507 (Dec 14, 2005) (6 pages) doi:10.1115/1.2349555 History: Received September 21, 2004; Revised December 14, 2005

Background: Since the Hanshin-Awaji Earthquake Disaster, the number of isolated structures has been greatly increased. The natural period of the isolation system is designed around 3s, because the predominate period of observed seismic waves is usually 0.1 to 1s. However, relatively long period seismic waves have been observed in various earthquakes, and the resonances of long-period structures, such as high-rise buildings, during earthquakes have been reported at the same time. Therefore the natural period needs to be extended. When extending the natural period of the isolated structure using rubber bearings, its stiffness needs to be reduced. It is more difficult to extend the natural period of the isolation system than the conventional system because of a buckling problem. Therefore we propose a super-long-period active seismic isolation system as a new method for extending the natural period of the isolated structure. This system consists of rubber bearings and hydraulic actuators. Method of approach: In this study, we designed a control system by using the model matching method. This is one of the classical control system design methods. Additionally we applied a genetic algorithm (GA) to select parameters of a transfer function. Results: The system designed by applying the GA could reduce response acceleration sufficiently compared with the input acceleration. Further waveforms of the response acceleration retain almost straight forwardly, so this indicates good performance of isolation. Therefore, application of super-long-period active isolation is an effective technique to improve the performance of isolation. However, the control forces are big, and the system needs 95.5×106N for the El Centro NS wave as control force. This force is equivalent to 21 actuators that are used in a large shake table, so there are few possibilities to realize active isolation. Conclusion: The required control force of hydraulic actuators is big, although the super-long-period active isolation system possesses good performance of isolation compared with the conventional isolation system. Therefore it is difficult to apply this isolation system to the real structure. However, the problem regarding requirements of the actuator should be solved because of the realization of an active seismic isolation system. Therefore, we will examine for the parameters of the system and semi-active isolation system.

FIGURES IN THIS ARTICLE
<>
Copyright © 2006 by American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Grahic Jump Location
Figure 1

Analytical model for passive isolation

Grahic Jump Location
Figure 2

The properties of artificial wave

Grahic Jump Location
Figure 3

Maximum response values

Grahic Jump Location
Figure 4

Analytical model for active isolation

Grahic Jump Location
Figure 6

Simulation results of frequency response

Grahic Jump Location
Figure 7

Simulation results of frequency response

Grahic Jump Location
Figure 8

Comparison of the analysis result

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In