Combined Effects of Tube Projection, Initial Tube-Tubesheet Clearance, and Tube Material Strain Hardening on Rolled Joint Strength

[+] Author and Article Information
N. Merah

Department of Mechanical Engineering, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabianesar@kfupm.edu.sa

A. Al-Aboodi

 Buraydah College of Technology, Buraidah, Al-Qassim 51432, Saudi Arabia

A. N. Shuaib, Y. Al-Nassar

Department of Mechanical Engineering, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabia

S. S. Al-Anizi

Department of Consulting Services, Saudi Arabian Oil Company, Dhahran 31311, Saudi Arabia

J. Pressure Vessel Technol 131(5), 051201 (Jul 24, 2009) (6 pages) doi:10.1115/1.3142387 History: Received February 19, 2008; Revised March 03, 2009; Published July 24, 2009

The tube-to-tubesheet joint strength is measured in terms of interfacial pressure between the tube’s outer surface and tubesheet bore. The strength of a rolled joint is influenced by several design parameters, including the type of tube and tubesheet materials, initial tube projection, and the initial radial clearance between the tube and tubesheet, among other factors. This paper uses finite element analysis (FEA) to evaluate the effect of several parameters on the strength of rolled joints having large overtolerances, a situation that applies to used equipment. An axisymmetric finite element model based on the sleeve diameter and rigid tube expanding roller concepts was used to analyze the effects of tube projection, initial tube-tubesheet clearance, and tube material strain-hardening property on the deformation behavior of the rolled tube and on the strength of the tube-tubesheet joint. The FEA results show that for zero tube projection (flush) the initial clearance effect is dependent on the strain-hardening capability of the tube material. For low strain-hardening tube material the interfacial pressure remains constant well above the Tubular Exchanger Manufacturer’s Association maximum overtolerance. A drastic reduction in joint strength is observed at high values of radial clearances. The cut-off clearance (clearance at which the interfacial pressure starts to drop) is found to vary linearly with the tube material hardening level, and the contact stress increases slightly for moderate strain-hardening tube materials but shows lower cut-off clearance levels. Furthermore, with flush tubes the maximum contact pressure occurs close to the secondary face (at the end of rolling) while for joints with initial tube projection the contact pressure shows two maxima occurring near the primary and the secondary faces. This is attributed to the presence of two elbows in tube deformation near the primary and secondary faces. The average interfacial pressure increased with increasing projection length for all clearances. Tube material strain hardening enhances the interfacial pressure in a similar fashion for all initial tube projection lengths considered in the analysis.

FIGURES IN THIS ARTICLE
<>
Copyright © 2009 by American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Grahic Jump Location
Figure 1

Schematic representation of tube-tubesheet joint with initial tube projection

Grahic Jump Location
Figure 2

FE model geometry and dimensions in millimeters

Grahic Jump Location
Figure 3

Meshed axisymmetric model

Grahic Jump Location
Figure 4

Radial deformation profiles of the inner and outer surfaces of the tube expanded in a joint with zero clearance

Grahic Jump Location
Figure 5

Radial deformation profiles of the inner and outer surfaces of the tube expanded in a joint with 0.127 mm clearance

Grahic Jump Location
Figure 6

Contact stress versus clearance for flush tube and different Ett with WR=5%

Grahic Jump Location
Figure 7

Contact stress (in pascals) distributions for flush tube and tube initial projection

Grahic Jump Location
Figure 8

Combined effects of tube material strain hardening, Ett, and the length of tube projection for a joint with a clearance of 0.127 mm and 5% tube wall reduction

Grahic Jump Location
Figure 9

Combined effects of clearance and tube projection length for a plastic tangent modulus of 0.8 GPa and 5% WR

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In